Product Category

OPEN-TYPE-DIESEL-GENERATOR-SETS OPEN-TYPE-DIESEL-GENERATOR-SETS

loading

OPEN-TYPE-DIESEL-GENERATOR-SETS

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button
Availability:
Quantity:

 

GENERATOR SETS POWERED BY FAW ENGINE
















MAIN SPECIFICATION OF DIESEL GENERATOR SETS (50HZ)
GENSET
MODEL
Open type modelGDF15GDF20GDF25GDF30GDF30GDF30GDF40GDF38GDF50GDF50GDF63GDF63GDF80GDF100GDF125GDF150GDF188GDF225GDF250GDF313GDF338
Soundproof modelGDF15SGDF20SGDF25SGDF30SGDF30SGDF30SGDF40SGDF38SGDF50SGDF50SGDF63SGDF63SGDF80SGDF100SGDF125SGDF150SGDF188SGDF225SGDF250SGDF313SGDF338S
Prime output(kVA/kW)15/1220/1625/2030/2430/2430/2440/3238/3050/4050/4063/5063/5080/64100/80125/100150/120188/150225/180250/200313/250338/270
Standby output (kVA/kW)16.5/13.222/17.627.5/2233/26.433/26.433/26.444/35.241.8/3355/4455/4468.8/5568.8/5588/70110/88138/110176/140206/165248/198275/220344/275375/300


DIESEL ENGINE MODEL4DW81-23D4DW91-29D4DW92-35D4DW92-39D4DW93-42D4DX21-45D4DX21-53D4DX22-50D4DX22-65D4DX23-65D4DX23-78D4110/125Z-09DCA4DF2-12DCA6DF2D-14DCA6DF2-17DCA6DF2-19DCA6DL1-24DCA6DL2-27DCA6DL2-30DCA6DM2J-39DCA6DM2J-41DCA6DN1J-45D
ENGINE CHARACTERSWater-cooled,in line,4-stroke,direct injection,wet cylinder liner,1500rpm
Prime Output (KW)1721262931333937484857658496125140176205227287300332
Standby Output (KW)192329323436434152.8 5362.7 7292105138154194226251316330365
AspirationNNTTT&INNTTT&IT&ITT&ITTT&IT&IT&IT&IT&IT&IT&I
NO. of Cylinder46
Bore x Stroke (mm)85x10090x10090x10090x10090x100102*118102*118102*118102*118102*118102*118110*125110*125110*115110*125110*125110*135112*145112*145123*155123*155131*155
Displacement (L)2.27 2.54 2.54 2.54 2.54 3.86 3.86 3.86 3.86 3.86 3.86 4.75 4.75 7.13 7.13 7.13 7.70 8.57 8.57 11.04 11.04 12.53 
Compression Ratio17:0117:0117:0117:0117:0117:0117:0117:0117:0117:0117:0117:0117:0117:0117:0117:0117.5:0117.5:0117.5:0117.5:0117.5:0118:1
Emission CertificationStage II
Governor Regulation≤5%≤3%
Rated Fuel Consumption@100% Load ( g/kWh)240240230230216230230220220215215215205202 202 200 196 195 195 195 195 195 
Governor  MechnicalMechnicalMechnicalElectronicMechnicalMechnicalElectronicMechnicalElectronicMechnicalElectronicElectronicElectronicElectronicElectronicElectronicElectronicElectronicElectronicElectronicElectronicElectronic
Alternator ModelJDG164DJDG184EJDG184FJDG184GJDG184GJDG184GJDG224CJDG184HJDG224DJDG224DJDG224EJDG224EJDG224GSJDG274CJDG274DSJDG274FJDG274GJDG274JJDG274KJDG314ESSJDG314EJDG314FS
Prime Output (kVA/kW)16/12.822.5/1827.5/2231.3/2531.3/2531.3/2542.5/3437.5/3050/4050/4060/4860/4880/64100/80120/96160/128190/152230/184250/200313/250350/280380/304
Power Efficiency81.00%84.90%85.7%86.6%86.6%86.6%86.6%86.6%87.7%87.7%88.3%88.3%89.8%89.8%90.3%92.0%92.0%92.4%92.5%93.6%93.2%93.4%
CHARACTERS4 Pole, Rotating Field,Brushless, Self excited,H class insulation,IP22,AVR460/440 ,12 WINDING LEADS.
Voltage Regulation±1.0% with4% engine governing
Open Type Dimensions
(LXWXH) m
1500x750x11501500x750x11501600x750x11501700x750x12001800x750x13002000x850x15002200x900x15002200x900x16002200x900x16002300x1000x17002500x1000x17002700x1000x17002800x1000x1700
Weight (KG) (2) 55060065070070080082083085088090011001140120013001700200022002500
Soundproof Type Dimensions
(LXWXH) m
1890×850×11502010×870×12002250×950×13002260×1010×14902410×960×15102860×1080×15903150×1075×16103160×1080×16103300×1200×18053950×1550×21003950×1410×2110
Weight (KG)80090011001150120013001350165017601800190020002900400041005000
Notes: (1)Above based on voltage 220/380V.
(2)The weights are approximate and without fuel.
(3)In line with our policy of continuous product development, we reserve the right to change specification without notice.
(4)N=Natural,T=Turbo-charged,T&CAC=Turbocharged and Charge Air Cooled,T&AAC=Turbocharged,Air-Air Cooled,T&AAA=Turbocharged and Air to Air Aftercooled,T&A=Turbocharged,T&I=Turbo &Intercooler,T&LTA=Turbocharged and Low Temperature Aftercooled & Aftercooled.
Rating Definitions
Prime Power Rating
Applicable for supplying electric power in lieu of commercially purchase power. Prime Power applications must be in the form of one of the following.
Unlimited Time Running Prime Power
Prime Power is available for an unlimited number of hours per year in a varible load application. Variable load should not exceed a 70% average of the Prime. 
Power rating during any operating period of 250 hours.The total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload 
capability is available for a period of 1 hour within a 12-hour period of operation. Total operationg time at the 10% overload power shall not exceed 25 hours 
per year.


Previous: 
Next: 
QUALITY
ASSURANCE
Copyright  2019 Goldlink Power Jiangsu Co.,Ltd.